Aluminum Ventilation Impeller for Building

Product Details
Customization: Available
Material: PA/Pag/Pagst/Pacas
Flow Direction: Axial Flow
Still deciding? Get samples of US$ 10/Piece
Request Sample
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 10 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Fast Delivery
The supplier can deliver the goods within 15 days
Customization from Samples
The supplier provides sample based customization services
to see all verified strength labels (12)
  • Aluminum Ventilation Impeller for Building
  • Aluminum Ventilation Impeller for Building
  • Aluminum Ventilation Impeller for Building
  • Aluminum Ventilation Impeller for Building
  • Aluminum Ventilation Impeller for Building
  • Aluminum Ventilation Impeller for Building
Find Similar Products

Basic Info.

Model NO.
P4Z
Pressure
High Pressure
Certification
RoHS, ISO, CE
Diameter
500-600mm
Speed
1450-2800rpm
Blade No.
4-12
Angle
35-40 Degree
Air Volume
6000-26000 M3/H
Transport Package
Carton Box
Specification
P4/P5
Trademark
Utek
Origin
China
HS Code
8414
Production Capacity
50000PCS/Year

Product Description

Airfoil profile P4Z is commonly used type for small and medium sized radiator, air conditioner. Blade made of aluminum alloy can be used for fireproof ventilation equipment. Impeller made of explosion proof material can be used for oil, gas and coal equipment.
 
Impeller diameters range from 250mm to 900mm with pitch angles from 25° To 50° . P4Z blade is mounted by means of a common blade root deign. The blades are fixed in the hub by means of a steel pin, ensuring a preset blade angle that cannot move or change under load.

Impeller diameters range from 310mm to 1100mm with pitch angles from 25°to 50°, the P5Z is geometrically scaled-up versions of the P4Z blade mounted by means of a common blade root deign. The blades are fixed in the hub by means of a steel pin, ensuring a preset blade angle that cannot move or change under load.

 
Type Diameter Speed Blade number Angle  Static pressure Air volume Consume
power
mm rpm n ° Pa m³/h m³/s w
P4 500 1450 4 35 85 6027 1.67 450
P4 500 1450 6 35 130 5890 1.64 615
P4 500 1450 7 35 130 5900 1.64 637
P4 500 1450 8 35 130 6000 1.67 780
P4 500 1450 9 35 130 6500 1.81 750
P4 500 2800 4 40 380 12000 3.33 4,190
P4 500 2800 6 40 400 14000 3.89 5,537
P4 500 2800 7 40 400 14500 4.03 5,600
P4 500 2800 8 40 400 13400 3.72 6,800
P4 500 2800 9 40 500 14000 3.89 6,703
P4 600 1450 4 38 100 11000 3.06 1,000
P4 600 1450 6 38 120 12000 3.33 1,350
P4 600 1450 7 38 150 11300 3.14 1,500
P4 600 1450 8 38 160 11000 3.06 1,700
P4 600 1450 9 38 160 11800 3.28 1,650
P4 600 2800 4 40 390 22000 6.11 8,050
P4 600 2800 6 40 400 25400 7.06 11,090
P4 600 2800 7 40 400 25500 7.08 11,900
P4 600 2800 8 40 430 24500 6.81 13,000
P4 600 2800 9 40 440 26000 7.22 12,000
P4 600 1450 4 40 90 11700 3.25 1,100
P4 600 1450 6 40 110 13000 3.61 1,500
P4 600 1450 7 40 120 13000 3.61 1,650
P4 600 1450 8 40 130 12300 3.42 1,900
P4 600 1450 9 40 135 13200 3.67 1,750
P4 600 1450 12 40 140 12600 3.50 2,040
P4 600 2800 4 35 400 19500 5.42 6,300
P4 600 2800 6 35 410 22700 6.31 8,510
P4 600 2800 7 35 420 22500 6.25 9,300
P4 600 2800 8 35 430 17500 4.86 6,800
P4 600 2800 9 40 500 25500 7.08 12,800
P4 600 2800 12 40 600 23000 6.39 14,900
 
Type diameter speed Blade number angle  static pressure air volume Consume
power
mm rpm n ° Pa m³/h m³/s w
P5 700 1450 6 35 200 15000 4.17 2,150
P5 700 1450 7 40 220 16800 4.67 2,980
P5 700 1450 8 40 220 17800 4.94 3,600
P5 700 1450 9 40 200 19000 5.28 3,300
P5 700 1450 12 40 200 20000 5.56 4,400
P5 700 1450 12 45 250 20000 5.56 5,700
P5 700 1450 6 30 150 14500 4.03 1,500
P5 700 1450 6 33 150 15500 4.31 1,800
P5 700 1450 7 35 150 17000 4.72 2,170
P5 700 1450 7 30 130 14500 4.03 1,500
P5 700 1450 8 30 130 15600 4.33 1,980
P5 700 1450 9 35 130 18500 5.14 2,400

Aluminum Ventilation Impeller for Building
Aluminum Ventilation Impeller for Building
Aluminum Ventilation Impeller for Building

Aluminum Ventilation Impeller for Building
Aluminum Ventilation Impeller for Building

Q&A:
1. What's your main business, composite material or axial fan?
Tailor made axial fan is our newly developed business. It's very successful since its establishment in last year
2. Why choose us?
We have a professional team who used to work for multi-wing for many years. Our quality is equal or even better than Multi-wing fan.
3. Can I order just one piece?
Yes, our fan is tailor-made. We can design and manufacture for you even you only need one piece.

Give us a chance, and we' ll return you with satisfaction. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier